USAfixTM - Repair Guide (RG) - Master Email RG
- Check for Power to the Solution Pump
 Level of Difficulty - HIGH  Estimated Completion Time - 10 minutes
TASKI - SWINGO 750B

Tools Required
Tool 
Volt meter (True RMS capable)
Wrench-Allen metric 6.0mm

Parts Required


Step Procedure & Parts & Tools
1 REMOVE THE 2 SHROUD BOLTS ON EACH SIDE OF THE MACHINE
Wrench-Allen metric 6.0mm

2 LOCATE THE SOLUTION PUMP AND WIRING

3 LOCATE THE SOLUTION PUMP WIRES AND DISCONNECT THE WIRE CONNECTORS

4 INSERT THE VOLT METER PROBES INTO THE WIRE CONNECTORS (THE WIRES FROM THE POWER BOARD TO THE SOLUTION PUMP). TURN THE MACHINE ON AND PUSH THE SOLUTION BUTTON TO TURN ON SOLUTION. VOLT METER SHOULD READ APPROX. 24 VOLTS.
Volt meter (True RMS capable)